Why ZX self-priming sanitary pump fails to suck liquid and how to fix?
The ZX self-priming sanitary pump may fail to suck liquid during initial use or after long-term shutdown. According to the technical specifications, troubleshooting should focus on three aspects: priming liquid amount, pipeline sealing and key components status.
For complete suction failure, check if the pump body contains enough priming liquid (about 2/3 of chamber volume). The solution includes injecting clean water through the filling hole and waiting 3 minutes before restarting.
If sudden suction stop occurs during operation, inspect air leaks in suction pipes. The manual requires pipe length within 3 meters without valves or elbows. Use soap water to detect leaks at connections.
For unstable flow, examine mechanical seal (model 104-22/108-25) damage and impeller clearance (should be 0.3-0.5mm). Replace seals following the diagonal tightening sequence in the manual.
When head pressure is insufficient, clean the gas-liquid separation chamber and verify discharge pipe configuration (no elbows within 1m vertical distance from pump outlet).