How to troubleshoot DP series micro diaphragm pump when no liquid flows after startup?
When <a href="/en/products/dp-micro-diaphragm-pump/" title="DP Series Micro Diaphragm Pump">DP Series micro diaphragm pump</a> shows no liquid flow after startup, first check the power supply voltage matches specifications (12V/24V DC or 220V AC). Use multimeter to verify voltage is within ±10% range.
Inspect pipeline connections for correct direction (follow arrow marking) and remove any blockages with compressed air. For complete pipeline clog, disassemble and flush with cleaning solvent.
If flow rate is insufficient, disassemble valve ball assembly to clean the 2-4mm balls and seats with ethanol. Check valve balls move freely and replace if stuck.
For intermittent flow issues, bleed air from pipeline and ensure suction side is fully submerged. Replace φ6×1.5mm O-rings at connections if leaking.