What are common issues in disassembling and repairing J series metering pump transmission case?
Transmission case is the core component of J series metering pump for power conversion.
Common issue - no discharge: Check motor operation first, then inspect intake pipe blockage or air leakage. Clean filter screen and replace damaged gaskets.
Insufficient flow solution: Measure valve ball roundness (replace if ovality >0.02mm) and adjust eccentric wheel stroke length with dial indicator.
Pressure fluctuation treatment: Install backpressure valve within 1m from discharge port and check valve spring elasticity (replace if length variation >10%).
Abnormal noise diagnosis: Use feeler gauge to check crosshead pin clearance (>0.15mm needs replacement) and relubricate bearings every 2000 operating hours.